ProSyllabus JournalAWS Certified Welding Inspector (CWI)

CWI Part B Practical Exam 2026: Book of Specifications and Worked Questions

How Part B of the AWS CWI exam works: 46 questions in 120 minutes, the materials and tools you get, how the Book of Specifications is laid out, worked decisions and the traps that cost marks.

Updated 1 week agoWelding Inspection · US Professional Certification · American Welding Society
#CWI Part B#CWI Part B practice test#CWI practical exam#Book of Specifications#AWS CWI#weld inspection
CWI Part B Practical Exam 2026: Book of Specifications and Worked Questions

Checked 30 October 2026. Format and materials as in the American Welding Society's Part B information guide (Rev. 03.01.2024) and Examination User Guide (09.04.2026); clause, table and annex numbers from the Part B Book of Specifications 2017, U.S. customary edition, read on 30 October 2026. Check AWS's CWI page for the edition linked for your exam.

Part B is the practical part of the AWS Certified Welding Inspector (CWI) exam set by the American Welding Society (AWS), and you take it first. It has 46 questions, a 120-minute limit and a pass mark of 72%. It is open book: the book is the Part B Book of Specifications (BOS), a sample code AWS wrote for the exam and publishes as a free PDF. AWS describes it as assessing whether you can evaluate a physical characteristic and make the correct decision against given acceptance criteria or code requirements: you measure or read something (a weld replica, a WPS, a PQR, a welder test record, a photograph) and decide what the BOS says about it. This guide shows how the BOS is laid out, what each tool is for, how to work a decision step by step and where candidates lose marks. ProSyllabus is an independent study site, not part of the American Welding Society.

46
questions, mostly multiple choice
120 min
about 2.6 minutes per question (our arithmetic)
72%
to pass: 34 of 46 correct (33 is 71.7%)
1st
Part B is taken before Parts A and C

AWS CWI Part B Practical Examination Information (Rev. 03.01.2024) and Examination User Guide for CWI (09.04.2026), read 23 Oct 2026.

FreeTests: Procedure and welder qualification · Welding inspection and flaws · Specifications and drawings

CWI Part B Practice Test: free sample

Answer 3 questions against the clock, like the real exam. You then see the right answer, the reason and your time on each. About 8 minutes · free · no sign-in.

3 questions to answer

Start nowabout 8 min

This one is free · no sign-in needed

Your result shows how long each question took you.

What you are given on the day

AWS's Part B information guide and Examination User Guide list four sets of material, all supplied at the test site. You answer from one or more of them:

MaterialWhat it isCan you see it before?
Part B Book of Specifications (BOS)A sample code written for the exam, with workmanship and visual acceptance criteria for structural steel, pipeline and pressure piping, plus procedure and welder qualification rules and annexesYes: a free PDF from AWS (U.S. customary for exams in the US and Canada, metric elsewhere)
Exam Exhibits BookletSample welding documents (WPSs, PQRs, WQTRs) and photographs, including photographs of NDE methodsNo: confidential
Four-piece plastic weld replica setA T-joint, a groove weld, bend specimens and a pipe specimenNo: confidential
Inspection tool kitFillet weld gauges, V-WAC gauge, dial caliper, ruler, C4.1 gauge, protractor, hi-lo gauge, magnifying glass, mirror, flashlightAWS sells a sample tool kit

Part B is a paper-based test at AWS test sites. The Examination User Guide says it runs in three sessions a day at each site, each with a 25-minute check-in window that closes five minutes before the listed approximate start time, and that doors close at the end of check-in: a late candidate is not admitted to another session. You sign a Candidate Attestation Agreement to keep the exam confidential before you start.

The tool kit

The kit holds fillet weld gauges, a V-WAC gauge, a dial caliper, a ruler, a C4.1 gauge, a protractor, a hi-lo gauge, a magnifying glass, a mirror and a flashlight. The BOS ties some of them to its own clauses: 1.2.1 allows a flashlight, magnifier and mirror as aids when inspecting for cracks and other discontinuities, and 2.2.1 judges cut edges against the AWS C4.1-77 roughness guide, which Annex V describes as both a written standard and a physical gauge for comparing oxyfuel-cut surfaces (Sample 1 the roughest, Sample 4 the smoothest).

The BOS says you are expected to know how to use and apply each instrument in the kit, including how to zero it where relevant. Measuring the plastic replicas is a hands-on skill: practise with a real kit if you can. The BOS also tells you to ignore pinholes, seams, glue and colour variations caused by the plastic moulding.

How the Book of Specifications is laid out

PartCoversApplies to
Clause 1General requirements: scope, shall / should / may, visual inspection aids, dimensional tolerances (1.3)All three applications, unless otherwise noted (1.1.3)
Clause 2Structural steel: base metal preparation, workmanship, Table 1 visual acceptance criteria (by statically loaded, cyclically loaded and tubular connections), Tables 2 and 3 weld profiles, fillet weld length and sizeStructural steel
Clause 3Pipeline: workmanship, repairs, and visual acceptance criteria for IP, IPD, IF, burn-through, porosity, cracks, undercut (Table 4) and accumulation of imperfectionsPipeline
Clause 4Pressure piping: workmanship, repairs and their examination, visual acceptance criteria, reinforcement by design temperature (Table 5)Pressure piping
Clause 5Procedure qualification: WPS data (Table 6), thickness limits (Table 7), PQR variables (Table 8), test specimens, bend and tension acceptanceAll three applications, unless otherwise noted (1.1.3)
Clause 6Welder performance qualification: variables, diameter and thickness limits (Tables 9, 10), tests (Tables 11, 12), base metals and filler metals (Tables 13, 14), positions (Table 15), test acceptanceAll three applications, unless otherwise noted (1.1.3)
Annexes I-IIIA-Numbers (weld metal analysis), F-Numbers (electrodes and rods), base metal specifications with M-Numbers, group numbers and minimum strengthsLook-ups for Clauses 5 and 6
Annex IVBend specimen preparationBend tests
Annexes V-VIFormulas (tensile strength, cross-sectional area), conversions, abbreviations, fraction-decimal table, pipe schedulesCalculations
Annexes VII-XBlank WPS, PQR and WQTR forms, and industry terms (such as high-low, crown, double repair, primary member)Reading documents

Two lines in the BOS shape the whole exam. Its foreword warns that it is formatted to look like a real codebook but is not one: read it carefully and do not rely on your memory of codebooks you know. And clause 1.1.4 says both its normative and informative annexes are part of the specification, so a value in an informative annex such as Annex V can be the basis of an answer.

FreeTests: Procedure and welder qualification · Welding inspection and flaws · Specifications and drawings

CWI Part B Practice Test: free sample

Answer 3 questions against the clock, like the real exam. You then see the right answer, the reason and your time on each. About 8 minutes · free · no sign-in.

3 questions to answer

Start nowabout 8 min

This one is free · no sign-in needed

Your result shows how long each question took you.

The five Part B domains

CWI Part B: minimum share of questions by domain
Welding Inspection and Flaws34%
Procedure and Welder Qualifications28%
Mechanical Test and Properties8%
NDE8%
Utilization of Specification and Drawings8%

AWS CWI Part B Practical Examination Information (Rev. 03.01.2024). Each figure is a minimum.

Part B domainMinimum shareTypical decision
Welding Inspection and Flaws34%Accept or reject a discontinuity on a replica or in a narrative under Clause 2, 3 or 4
Procedure and Welder Qualifications28%Is this WPS supported by this PQR? What does this welder's test qualify?
Mechanical Test and Properties8%Does a tension or bend specimen pass? Was a bend specimen prepared correctly?
NDE8%Which method is shown, which step, which method the BOS requires for a repair
Utilization of Specification and Drawings8%Read a tolerance, an annex or a drawing dimension

Shares are minimums from AWS's Part B information guide. Together they add up to 86% (our arithmetic). At least 28% of the questions concern procedure and welder qualification, on documents and on specimens, so Tables 7, 8, 9, 10 and 15 repay steady practice.

Worked decisions, step by step

Each example below uses our own numbers, the way a Part B question gives you a measurement or a document and asks for the decision. Clause and table numbers are from the BOS 2017 U.S. customary edition.

1. Undercut on a structural weld

  • You measure undercut 1/32 in deep on a fillet weld in 1-1/2 in thick plate, in a statically loaded nontubular connection.
  • Step 1: find the application and the connection type. Structural steel, so Clause 2 and Table 1; statically loaded nontubular, so the first column.
  • Step 2: find the row. Table 1, item (7)(A): for material 1 in thick or more, undercut may not exceed 1/16 in.
  • Decision: accept. 1/32 in is less than 1/16 in. The same undercut on a primary member of a cyclically loaded connection, with the weld transverse to tensile stress, would be judged under item (7)(B) against 0.01 in, and rejected.

2. Undercut on a pipeline weld: "whichever is smaller"

  • A pipeline weld joins pipe with a 0.200 in wall. You measure external undercut 1/32 in deep and 1-1/2 in long; the weld is 40 in around.
  • Step 1: Table 4 compares depth with a fixed value and with a percentage of the wall, and uses whichever is smaller. 12.5% of 0.200 in = 0.025 in, which is smaller than 1/32 in (about 0.031 in); 6% of 0.200 in = 0.012 in, smaller than 1/64 in (about 0.0156 in).
  • Step 2: 1/32 in (0.031 in) is over 0.025 in, so it falls in the top row of Table 4.
  • Decision: reject, at any length. On a thicker wall the same undercut could have fallen in the middle row, where length decides.

3. A PQR's thickness range

  • A SMAW groove PQR was welded in 5/8 in plate, with no single pass over 1/2 in, no PWHT and no fracture toughness requirement; the contractor wants to weld 1-1/8 in plate on a WPS it supports.
  • Step 1: Table 7, the row for test weldments over 3/8 in but less than 3/4 in: the base metal range is 3/16 in to 2T.
  • Step 2: 2 x 5/8 in = 1-1/4 in. Notes (d) and (e) would cut the maximum to 1.1T, and note (c) would raise the minimum for fracture toughness work, but none applies here.
  • Decision: the thickness is supported, since 1-1/8 in is inside 3/16 in to 1-1/4 in, provided the WPS meets every other Table 8 variable.

4. What a welder's test position covers

  • A welder passed a 2G plate groove test. Production needs a vertical fillet weld and a horizontal groove weld in 30 in OD pipe.
  • Step 1: Table 15, plate groove 2G: groove F and H for plate and pipe over 24 in OD; fillet F and H.
  • Step 2: the horizontal groove in 30 in pipe is covered (pipe over 24 in OD, position H). The vertical fillet is not: 2G gives fillets F and H only.
  • Decision: the groove weld position is covered (provided the welder meets the other 6.2 limits); the vertical fillet is not.

FreeTests: Procedure and welder qualification · Welding inspection and flaws · Specifications and drawings

CWI Part B Practice Test: free sample

Answer 3 questions against the clock, like the real exam. You then see the right answer, the reason and your time on each. About 8 minutes · free · no sign-in.

3 questions to answer

Start nowabout 8 min

This one is free · no sign-in needed

Your result shows how long each question took you.

Traps that cost marks

  • The wrong application. Undercut, porosity and reinforcement limits differ between Clause 2 (structural), Clause 3 (pipeline) and Clause 4 (pressure piping). Read the question for the application before you open a table.
  • The wrong column of Table 1. Several structural limits apply only to statically loaded, or only to cyclically loaded and tubular, connections. Check the column before the value.
  • "Whichever is smaller" or "whichever is less". Table 4 (pipeline undercut), 3.2.4 (burn-through), 4.1.5 (interrupting a preheated joint), 4.1.9.3 (repair depth), 5.4.1 and 6.4.1 (undercut on test welds) all compare two limits. Work out both.
  • The thinner material. Pressure piping reinforcement (Table 5, note 3) is based on the thinner of the materials joined; a pipeline pore limit (3.2.5) is 25% of the thinner wall.
  • Tolerances that do not apply. The fractional tolerances of 1.3.2 apply to weld length and pitch (2.4.1) but not to fillet weld size (2.4.2); clause 1.3 also excludes test specimens and discontinuity limits. Undersize allowances for fillets are in Table 1, item (6).
  • Procedure rules versus welder rules. A change that needs a new PQR (Table 8) is not the same list as a change that needs the welder to retest (6.2). A change in shielding gas composition is a Table 8 variable but not a 6.2 welder variable (6.2 lists only the deletion of root shielding gas, for GMAW and GTAW).
  • "Q" and "T" in Table 8. Variables marked T apply only when fracture toughness testing is required. A heat input increase, for example, is a T variable (and Table 8 excepts it when a grain-refining austenitizing heat treatment follows welding).
  • Fractions and decimals. Many limits are fractions and many readings decimals. Annex V Table 18 gives the equivalents, cut to three places: 1/64 in (0.015625 in) is listed as .015 there.

Pacing 46 questions in 120 minutes

120 minutes for 46 questions is about 2 minutes 37 seconds each (our arithmetic). Our suggestion: measuring a replica usually takes longer than looking up a table, so answer the look-ups quickly, mark any measurement you are unsure of, and come back to it. Read every option before you choose: the BOS instructions say there is only one correct answer, so check that your choice uses the right table, row and column. Transfer each answer to the correct place on the answer sheet, as the BOS reminds you, and keep calculations to the margins of your exam booklet: the BOS itself must not be written on.

How to prepare for Part B

  • Download the Book of Specifications for your exam (U.S. customary for the US and Canada) and learn where every table is. You cannot write in the exam copy, so the layout has to be in your head.
  • Work through Tables 7, 8, 9, 10 and 15 with your own examples until a range or a position takes you under a minute.
  • Practise the decision on documents: read a WPS, a PQR and a welder test record together and say what each supports.
  • If you can, handle a real tool kit: zero the dial caliper, read the V-WAC gauge, use the fillet gauge on convex and concave welds.
  • Time yourself: 46 questions in 120 minutes, then review every answer against the BOS clause.
  • AWS also runs a three-day Part B seminar (Book of Specifications review, WPS and PQR analysis, tools and replicas, a timed practice exam); its exam-plus-training price is on the CWI page.

Try a Part B-style question

Practice question · Part B style · Welding inspection and flaws

A drawing specifies a continuous 1/4 in fillet weld. Over part of its length you measure 3/16 in. Under BOS Table 1, may it stay without correction?

  • A. Yes: 1/4 in may be up to 3/32 in under size (5/32 in minimum).
  • B. Yes, but only if the undersized stretch is at one end.
  • C. No: a 1/4 in weld may be only 1/32 in under size, so 7/32 in is the minimum.
  • D. No: fillet weld size is a minimum, so no part of it may be under 1/4 in.
Show the answer and why

Answer: A.

BOS Table 1, item (6): for a specified nominal size L of 1/4 in, the allowable decrease U is up to 3/32 in, so 1/4 - 3/32 = 5/32 in is the smallest acceptable size. 3/16 in (6/32 in) is larger than 5/32 in, so no correction is needed.

An original ProSyllabus practice question, answered from the free Part B Book of Specifications 2017. It is not an AWS exam question.

FreeTests: Procedure and welder qualification · Welding inspection and flaws · Specifications and drawings

CWI Part B Practice Test: free sample

Answer 3 questions against the clock, like the real exam. You then see the right answer, the reason and your time on each. About 8 minutes · free · no sign-in.

3 questions to answer

Start nowabout 8 min

This one is free · no sign-in needed

Your result shows how long each question took you.

Frequently asked questions

How many questions are on CWI Part B?

AWS's Part B information guide says 46, with a maximum of 120 minutes and 72% needed to pass. The questions are mostly multiple choice.

Is CWI Part B open book?

Yes. The reference is the Part B Book of Specifications, supplied at the test site and available as a free PDF from AWS. You also get an exhibits booklet, a plastic weld replica set and an inspection tool kit.

Can I see the Part B exhibits and replicas before the exam?

No. AWS says the exhibits booklet and the replica set are confidential. The Book of Specifications is free to download, and AWS sells a sample tool kit.

Which Book of Specifications should I use?

The one AWS links for your exam: the U.S. customary edition for English exams in the United States and Canada, and the metric edition for exams elsewhere. The U.S. customary BOS PDF we read on 30 October 2026 is dated 2017.

Do I take Part B before Part A and Part C?

Yes. AWS's Examination User Guide requires Part B first; Parts A and C can be scheduled at Prometric only after you receive the Part B confirmation letter.

Is the Book of Specifications the same as AWS D1.1?

No. It is a sample code written for the exam, covering structural steel, pipeline and pressure piping. Some clauses look like real codes, but the BOS itself warns you not to rely on memory of them.

How many questions must I get right to pass Part B?

72% of 46 is 33.12, and AWS reports scores to the nearest lower whole percent, so you need 34 correct: 33 is 71.7%, reported as 71% (our arithmetic).

  • 92 original Part B questions
  • Two 46-question mocks, 120 minutes each
  • All 5 Part B domains
  • Book of Specifications references in the answers
  • Every answer explained
  • A score by domain
Free try up to 8 min, Each mock up to 2 h
₹2,299
Try questions freeup to 8 minView details

Get alerts for AWS Certified Welding Inspector (CWI)

Dates, results and cutoffs, by email when they are announced. Free.

Google, Apple, or a code to your phone or email. It is saved to your account.

More on AWS Certified Welding Inspector (CWI)The exam page: every guide for this exam in one place

More on AWS Certified Welding Inspector (CWI)1 guides

Notebook backup + AISave your notes. Revise with AI.Learn more →

Discussion

No discussions yet.

Share this article

Free try up to 8 min, Each mock up to 2 h
Try freeup to 8 min

View details

Disclaimer

Independent practice, not written or endorsed by the American Welding Society. Original questions, not AWS exam questions; no Book of Specifications text is reproduced.